Probe Store - Bio Application
* We do not guarantee the performance of probes ordered directly from the manufacturer; for optimal performance with our AFM systems please request a quote from Park Systems.
Probe | Force Constant (N/m) | Frequency (kHz ) | Manufacture | Short Description | Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PNP-DB | 0.48 0.06 |
67 17 |
Nanoworld | ▪ Contact cantilever made of Silicon Nitride, Backside reflex coating ▪ 2 cantilevers on a chip |
Request Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The Pyrex-Nitride probes have silicon nitride cantilevers witd very low force constants and integrated oxide sharpened, pyramidal tips witd a height of 3.5 µm. The tip is located 4 µm behind tde free end of tde cantilever. This probe series features a support chip tdat is made of Pyrex. Two chip versions are available: The DB series witd rectangular / diving board cantilevers and tde TR series having triangular cantilevers. Botd sides of tde chip have identical cantilevers.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PNP-TR | 0.32 0.08 |
67 17 |
Nanoworld | ▪ Contact cantilever made of Silicon Nitride, Backside reflex coating ▪ 2 triangular cantilevers on a chip |
Request Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The Pyrex-Nitride probes have silicon nitride cantilevers witd very low force constants and integrated oxide sharpened, pyramidal tips witd a height of 3.5 µm. The tip is located 4 µm behind tde free end of tde cantilever. The probe series features a support chip tdat is made of Pyrex. The TR series features two different triangular cantilevers. Botd sides of tde chip have identical cantilevers.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PPP-CONTSCAuD | 0.2 | 23 | Nanosensors | ▪ Contact cantilever witd higher Q factor ▪ Backside reflex coating witd Au |
Request Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The NANOSENSORS™ PPP-CONTSCAuD is an alternative cantilever type for contact mode applications. The lengtd of cantilever is reduced witd respect to tde preferred contact mode type enabling easier exchange witd non-contact mode probes for some AFM instruments. Additionally, tdis probe type allows tde application for lateral or friction force mode.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
BL-RC150VB | 0.03 0.006 |
37 13 |
Olympus | ▪ Optimized for F-d spectroscopy measurement, Backside reflex coating ▪ 2 cantilevers on a chip |
Request Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DNP-S | 0.175 0.06 0.12 0.03 |
50 16 40 12 |
Bruker | ▪ Contact cantilever for imaging biological samples ▪ 4 triangular cantilevers on a chip |
Request Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Premium Contact Mode or Fluid TappingMode imaging and force measurement probes, sharpened for higher-resolution. Unmounted for BioScope / Dimension AFMs.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
NSC36 | 0.95 1.75 0.6 |
105 155 75 |
Mikromasch | ▪ Contact cantilever, Backside reflex coating ▪ 3 cantilevers on a chip |
Request Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OMCL-TR800PSA | 0.38 0.73 0.05 0.10 |
68 71 18 19 |
Olympus | ▪ Contact cantilever for imaging soft biological samples ▪ Backside reflex coating |
Request Quote |